Strong versatility in BPH procedures, allowing enucleation, vaporization and resection of prostatic adenoma
Up to 200W power, for fast vaporization of prostatic adenoma
Strong hemostatic capabilities already while cutting, for limited blood loss during treatment
Limited depth of penetration (0.1-0.2 mm only)
Up to 100Hz frequency for fast pulse delivery during soft tissue surgery
Multidisciplinarity and versatility, thanks to the combination of fast cutting/ablation properties, limited damage and hemostasis
Wide range of fiber diameters and types available, for enhanced surgical versatility
Wheel dampers, for easy and safe relocation and transportation
Saving and Loading of customized preset modes
Side Fiber available for intuitive vaporization of prostatic adenoma (also achievable with frontal fiber)

150W - 200W THULIUM SURGICAL LASER SYSTEM

The device at a glance

Cyber TM represents the family of high power Thulium laser (150W and 200W) dedicated to BPH and urology treatments, together with other soft tissue surgery in many other medical specialties. 

Its 2 μm radiation is strongly absorbed by water (highly present in all tissues), making its cutting and vaporization speed relatively constant during the procedure regardless of tissue vascularization. Furthermore, this wavelength results in extremely reduced depth of penetration (0.1-0.2 mm), efficient tissue ablation and effective hemostasis. 

Strong BPH versatility

Enucleation and Vaporization of the adenoma are available with the same device, without constraints in technique selection. Thulium enucleation technique is feasible for both small and large prostatic adenoma size, highly customizable, with the possibility to switch quickly from cutting to coagulation thanks to the double footswitch. On the other hand, Thulium vaporization is an easy and intuitive procedure (it can be performed also with side fiber), obviating the use of morcellator and taking advantage of the 200W maximum power of this device for fast treatments. Alternatively, resection technique can be effectively performed too.

High emission power

Cyber TM thulium surgical laser is featured with an extremely high output power: 200W. A high emission power, in particular when coupled with the 1000 µm fiber or with the side fiber, enables fast ablation of the adenoma thanks to the powerful effect on very large areas.

Confined Damage
and Strong Hemostasis

The 2 µm radiation is strongly absorbed by water, resulting in minimal depth of penetration0.1-0.2 mm (on the side, tissue appearance after 24 hours upon vaporization). This interaction results in precise cut and ablation, providing the surgeon with a high degree of control and reducing the risk of inadvertent injury substantially. 

Furthermore, Thulium wavelength allows effective hemostasis already while cutting. 

Established Technology

Cyber TM device is a well-established laser technology on the global market. As demonstrated by its long presence on the market, (introduced in 2009) and more than 300 installations worldwide in over 25 different countries, this device represents a reliable and highly effective surgical solution for a large variety of surgical treatments.

Strong Multidisciplinarity

Thanks to its specific properties and minimal damage, Thulium laser allows effective excision, cutting, ablation and coagulation of soft tissues in different medical specialties. Apart from Urology, Cyber TM can be used also, for example, in Thoracic Surgery, Gastroenterology, ENT, General Surgery and Gynecology. Based on that, this laser device can address multiple needs from different wards of the same hospital. 

Thoracic and GI Surgery

Use of Thulium laser was proven to be effective not only in the urology field, but also in the thoracic field (e.g. endobronchial surgery) and in the gastroenterology field (with its ablation and coagulation effectiveness coming in handy for soft tissue surgery and hemostasis).

Some of these laser applications are detailed in published studies with Cyber TM. 

Clinical Evidences

Since its introduction to the market, use of Cyber TM device has been reported in multiple publications by different institutions. These publications and research activities provide strong clinical evidences regarding the safety and effectiveness of Cyber TM laser within different medical fields. Indeed, more than 50 publications detail the outcomes after the use of this laser in BPH, soft tissue urologic surgery, Thoracic surgery, Gastroenterology etc. 